Saturday, March 20, 2010

union metal roof - atap metal union

Data Teknis

SPAN TERMINOLOGY

MAXIMUM ALLOWABLE ROOF SUPPORT SPACING

Union Clip Panel

Type Of Span

Thickness (mm) BMT

0.45

Single Span

1000

End Span

1200

Internal Span

1700

Overhang

150

Union Deck

Type Of Span

Thickness (mm) BMT

0.35

0.4

0.45

Roofs

Single Span

500

700

1000

End Span

900

1200

1500

Internal Span

1500

1700

2100

Overhang

200

200

200

Walls

Single Span

2000

2300

2500

End Span

1000

1500

2000

Internal Span

1800

2000

2400

Overhang

200

200

200

Union MP-Deck

Type

Thickness (mm) BMT

0.35

0.4

0.45

Roofs

Single Span

500

700

1000

End Span

700

900

1000

Internal Span

1400

1600

1700

Overhang

200

200

200

Walls

Single Span

2400

2400

2400

End Span

1000

1400

1700

Internal Span

1700

1900

2100

Overhang

200

200

200

KEMIRINGAN ATAP MINIMUM

TYPEKEMIRINGAN ATAP

1 : 50 (1˚)

1 : 20 (3˚)

1 : 30 (2˚)

TEKANAN ANGIN YANG DIIJINKAN UNTUK ATAP

(0,50 mm TCT Thickness untuk atap)

TYPE

Jarak Peletakan

(mm)

Tekanan Angin Pada Tiap Bentang (Kg/m²)

900

1200

1500

1800

2100

Union Clip Panel®

1700

377

286

194

153

133

Union Deck®

2100

428

316

255

214

514

Union MP-Deck®170019414311210282

LIMPASAN AIR HUJAN PADA ATAP

Korelasi panjang lembaran atap dengan sudut kemiringan dan intensitas curah hujan

TYPE

Intensitas Curah Hujan mm/jam

Sudut Kemiringan (Derajat)

Panjang Atap (m)

1(1:50)

2(1:30)

3(1:20)

5(1:12)

10(1:60)

Union Clip Panel®

250

64

80

94

-

-

30053667895-
4004050587083
5003240465666

Union Deck®150-42485670
200-31364252
250-25283342
300-20332735
400-15172026

Union MP-Deck®200-505972-
250-40475774
300-34394761
400-25293546

No comments: